Diagnosis Procedure
- CHECK METER CONTROL SWITCH INPUT SIGNAL
- Turn the ignition switch ON.
- Measure voltage between the following terminals of the combination meter.
Combination meter Condition Voltage (Approx.) Connector Terminal (+) (-) M53 36 16 When • (select) switch is pressed 0 V Other than the above 5 V 37 16 When □ (enter) switch is pressed 0 V Other than the above 5 V 38 16 When trip A/B reset switch is pressed 0 V Other than the above 5 V 39 16 When ILLUMINATION CONTROL - (illumination control) switch is pressed 0 V Other than the above 5 V 40 16 When ILLUMINATION CONTROL + (illumination control) switch is pressed 0 V Other than the above 5 V Is the inspection result normal?
YES: INSPECTION END
NO: GO TO 2.
- CHECK METER CONTROL SWITCH SIGNAL CIRCUIT
- Turn the ignition switch OFF.
- Disconnect the combination meter and meter control switch connectors.
- Check continuity between combination meter harness connector terminal and meter control switch harness connector terminal.
Combination meter Meter control switch Continuity Connector Terminals Connector Terminals M53 16 M54 7 Existed 36 2 37 1 39 10 40 9 38 5 - Check continuity between combination meter harness connector terminal and ground.
Combination meter Ground Continuity Connector Terminals M53 36 Not existed 37 39 40 38 Is the inspection result normal?
YES: INSPECTION END
NO: Repair harness or connector.