Component Inspection
- CHECK METER CONTROL SWITCH UNIT
- Turn the ignition switch OFF.
- Disconnect the meter control switch connector.
- Check continuity of the meter control switch.
Terminal No. Operation and status Continuity 2 7 When • (select) switch is pressed Existed Other than the above Not existed 1 7 When □ (enter) switch is pressed Existed Other than the above Not existed 5 7 When trip A/B reset switch is pressed Existed Other than the above Not existed 10 7 When ILLUMINATION CONTROL - (illumination control) switch is pressed Existed Other than the above Not existed 9 7 When ILLUMINATION CONTROL + (illumination control) switch is pressed Existed Other than the above Not existed Is the inspection result normal?
YES: INSPECTION END
NO: Replace the meter control switch.