UNIFIED METER AND A/C AMP.: Diagnosis Procedure
- CHECK FUSE
Check 10A fuses [Nos. 3, 6 and 19, located in the fuse block (J/B)].
NOTE: Refer to "FUSE, CONNECTOR AND TERMINAL ARRANGEMENT ".Is the inspection result normal?
YES: GO TO 2.
NO: Check harness for short circuit and replace fuse.
- CHECK POWER SUPPLY CIRCUIT FOR UNIFIED METER AND A/C AMP.
- Disconnect unified meter and A/C amp. connector.
- Check voltage between unified meter and A/C amp. harness connector and ground.
(+) (-) Voltage Unified meter and A/C amp. - Ignition switch position Connector Terminal OFF ACC ON M67 41 Ground Approx. 0 V Battery voltage Battery voltage 53 Approx. 0 V Approx. 0 V Battery voltage 54 Battery voltage Battery voltage Battery voltage Is the inspection result normal?
YES: GO TO 3.
NO: Repair harness or connector.
- CHECK GROUND CIRCUIT FOR UNIFIED METER AND A/C AMP.