Diagnosis Procedure
- PERFORM SELF-DIAGNOSIS
Perform self-diagnosis function. Refer to "WITHOUT ACCS: DIAGNOSIS DESCRIPTION " (WITHOUT ACCS) or "WITH ACCS: DIAGNOSIS DESCRIPTION " (WITH ACCS).
Is the inspection result normal?
YES: INSPECTION END
NO: GO TO 2.
- PERFORM IPDM E/R AUTO ACTIVE TEST
Perform IPDM E/R auto active test. Refer to "DIAGNOSIS DESCRIPTION ".
Does the magnet clutch operate?
YES-1: WITH CONSULT: GO TO 5.
YES-2: WITHOUT CONSULT: GO TO 6.
NO: Check 10A fuse (No. 49, located in IPDM E/R), and GO TO 3.
- CHECK CIRCUIT CONTINUITY BETWEEN IPDM E/R AND COMPRESSOR
- Turn ignition switch OFF.
- Disconnect IPDM E/R connector and compressor connector.
- Check continuity between IPDM E/R harness connector and compressor harness connector.
IPDM E/R Compressor Continuity Connector Terminal Connector Terminal E7 48 F43 1 Existed Is the inspection result normal?
YES: GO TO 4.
NO: Repair harness or connector.
- CHECK MAGNET CLUTCH CIRCUIT
Check for operation sound when applying battery voltage direct current to terminal.
Is the inspection result normal?
YES: Replace IPDM E/R.
NO-1: VQ37VHR: Replace magnet clutch. Refer to "MAGNET CLUTCH: REMOVAL AND INSTALLATION OF COMPRESSOR CLUTCH ".
NO-2: VK50VE: Replace compressor. Refer to "REMOVAL AND INSTALLATION ".
- CHECK ECM INPUT SIGNAL-1
Check A/C switch signal in "Data monitor". Refer to "WITHOUT ACCS: CONSULT FUNCTION " (WITHOUT ACCS) or "WITH ACCS: CONSULT FUNCTION " (WITH ACCS).
A/C SWITCH ON: AIR COND SIG On
A/C SWITCH OFF: AIR COND SIG Off
Is the inspection result normal?
YES: GO TO 8.
NO: GO TO 6.
- CHECK REFRIGERANT PRESSURE SENSOR
WITH CONSULT
- Start the engine.
- Check voltage of refrigerant pressure sensor in "Data monitor". Refer to "REFERENCE VALUE " (VQ37VHR) or "REFERENCE VALUE " (VK50VE).
WITHOUT CONSULT
- Start the engine.
- Check voltage between ECM harness connector and ground.VOLTAGE REFERENCE (VQ37VHR)
(+) (-) Condition Voltage ECM - connector Terminal M107 105 Ground A/C switch: ON (Blower motor operates.) Approx. 1.0 - 4.0 V VOLTAGE REFERENCE (VK50VE)(+) (-) Condition Voltage ECM - connector Terminal F111 90 Ground A/C switch: ON (Blower motor operates.) Approx. 1.0 - 4.0 V Is the inspection result normal?
YES:
- WITH CONSULT: GO TO 7.
- WITHOUT CONSULT: Repair harness or connector.
NO: Refer to "DIAGNOSIS PROCEDURE " (VQ37VHR) or "DIAGNOSIS PROCEDURE " (VK50VE).
- CHECK ECM INPUT SIGNAL-2
Check blower fan motor switch signal in "Data monitor". Refer to "WITHOUT ACCS: CONSULT FUNCTION " (WITHOUT ACCS) or "WITH ACCS: CONSULT FUNCTION " (WITH ACCS).
FAN SWITCH ON: HEATER FAN SW On
FAN SWITCH OFF: HEATER FAN SW Off
Is the inspection result normal?
YES: GO TO 8.
NO: Repair harness or connector.
- CHECK CAN COMMUNICATION
Check CAN communication. Refer to "TROUBLE DIAGNOSIS FLOW CHART ".
- ECM - IPDM E/R
- ECM - Unified meter and A/C amp.
Is the inspection result normal?
YES: Replace ECM.
NO: Repair or replace malfunctioning part(s).