- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection M95. Refer to Ground Inspection in
"CIRCUIT INSPECTION
".
Is the inspection result normal?
YES: GO TO 2.
NO: Repair or replace ground connection.
- CHECK HEATED OXYGEN SENSOR 2 (HO2S2) POWER SUPPLY CIRCUIT
- Disconnect heated oxygen sensor 2 (HO2S2) harness connector.
- Turn ignition switch ON.
- Check the voltage between HO2S2 harness connector and ground.
DTC HO2S2 Ground Voltage Bank Connector Terminal P0037, P0038 1 F87 2 Ground Battery voltage P0057, P0058 2 F88 2 Is the inspection result normal?
YES: GO TO 4.
NO: GO TO 3.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E10, F10
- IPDM E/R harness connector E7
- 15 A fuse (No. 46)
- Harness for open or short between heated oxygen sensor 2 and fuse
: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK HO2S2 OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between HO2S2 harness connector and ECM harness connector.
DTC HO2S2 ECM Continuity Bank Connector Terminal Connector Terminal P0037, P0038 1 F87 3 F111 56 Existed P0057, P0058 2 F88 3 55 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 5.
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK HO2S2 HEATER
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 7.
NO: GO TO 6.
- REPLACE HEATED OXYGEN SENSOR 2
Replace malfunctioning heated oxygen sensor 2. Refer to "EXPLODED VIEW ".
CAUTION:- Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
- Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner [commercial service tool (J-43897-18 or J-43897-12)] and approved anti-seize lubricant (commercial service tool).
: INSPECTION END
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
: INSPECTION END