LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2013 >> FX37 Base, RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 6 (Heater & Air Conditioning System) >> Periodic Maintenance >> Refrigeration System >> Performance Chart >> Test Reading

Test Reading

WARNING: This page is about a different car, the 2013 Infiniti FX50. However, it is still accessible from the selected car via links, so may be relevant.
RECIRCULATING-TO-DISCHARGE AIR TEMPERATURE

Inside air (Recirculating air) at blower assembly inlet Discharge air temperature at center ventilator °C (°F)
Relative humidity % Air temperature °C (°F)
50 - 60 20 (68) 5.2 - 7.2 (41 - 45)
25 (77) 9.8 - 12.3 (50 - 54)
30 (86) 14.5 - 17.5 (58 - 64)
60 - 70 20 (68) 7.2 - 9.2 (45 - 49)
25 (77) 12.3 - 14.8 (54 - 59)
30 (86) 17.5 - 20.5 (64 - 69)
AMBIENT AIR TEMPERATURE-TO-OPERATING PRESSURE

Ambient air High-pressure (Discharge side) kPa (kg/cm2 , psi) Low-pressure (Suction side) kPa (kg/cm2 , psi)
Relative humidity % Air temperature °C (°F)
50 - 70 25 (77) 905 - 1, 060 (9.2 - 10.8, 131.3 - 153.7) 186 - 227 (1.9 - 2.3, 27.0 - 32.9)
30 (86) 1, 110 - 1, 358 (11.3 - 13.8, 161.0 - 197.0) 228 - 278 (2.3 - 2.8, 33.1 - 40.3)
35 (95) 1, 345 - 1, 643 (13.7 - 16.8, 195.1 - 238.3) 270 - 330 (2.8 - 3.4, 39.2 - 47.9)
40 (104) 1, 577 - 1, 736 (16.1 - 17.7, 228.7 - 251.8) 300 - 366 (3.1 - 3.7, 43.5 - 53.1)