LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2013 >> FX37 Base, RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 6 (Heater & Air Conditioning System) >> Periodic Maintenance >> Refrigerant >> Collection and Charge >> Setting Of Service Tools And Equipment >> Procedure

Setting Of Service Tools And Equipment: Procedure

WARNING: This page is about a different car, the 2013 Infiniti FX50. However, it is still accessible from the selected car via links, so may be relevant.
WARNING: Never breath A/C refrigerant and lubricant vapor or mist. Exposure may irritate eyes, nose and throat. Remove HFC-134a (R-134a) from A/C system using certified service equipment meeting requirements of SAE J-2210 [HFC-134a (R-134a) recycling equipment] or J-2209 [HFC-134a (R-134a) recovery equipment]. Ventilate work area before resuming service if accidental system discharge occurs. Additional health and safety information may be obtained from refrigerant and lubricant manufacturers.
  1. CHECK A/C SYSTEM 
    1. Check that A/C system operates normally. Refer to "WITHOUT ACCS: DESCRIPTION & INSPECTION " (Without ACCS) or "WITH ACCS: DESCRIPTION & INSPECTION " (With ACCS).
    2. Check if there is a large amount of leakage of refrigerant or oil.
      CAUTION: Never perform the lubricant return operation if a large amount of leakage of lubricant is detected.

      Is the inspection result normal? 

      YES: GO TO 2.

      NO: Check for refrigerant leakage. Refer to "INSPECTION ".

  2. LUBRICANT RETURN OPERATION 
    1. Start the engine and run it as follows.
      • Engine speed: Idle - 1, 200 RPM
      • A/C switch: ON
      • Fan (blower) speed: Maximum speed set
      • Set temperature: Full cold
      • Intake position: Recirculation (REC)
    2. Perform lubricant return operation for approximately 10 minutes.
    3. Stop the engine.

      : GO TO 3.

  3. CHECK RECOVERY/RECYCLING RECHARGING EQUIPMENT 
    1. Operate recovery/recycling recharging equipment.
      CAUTION:
      • Follow the instructions of the manufacturer for the handling or maintenance of the equipment.
      • Never fill the equipment with undesignated refrigerant.
    2. Check the gauge pressure of recovery/recycling recharging equipment.

      Is there pressure? 

      YES: GO TO 4.

      NO: GO TO  5.

  4. DISCHARGE REFRIGERANT INSIDE PIPES 

    Discharge the refrigerant from the high-pressure hose and low-pressure hose of recovery/recycling recharging equipment.

    : GO TO 5.

  5. CONNECT RECOVERY/RECYCLING RECHARGING EQUIPMENT 
    1. Remove the service valve caps from the vehicle.
    2. Connect recovery/recycling recharging equipment to the service valves.

      : GO TO 6.

  6. DISCHARGE REFRIGERANT FROM THE VEHICLE 

    Operate recovery/recycling recharging equipment to discharge the refrigerant from the vehicle.

    : GO TO 7.

  7. REMOVE ANY REMAINING REFRIGERANT 

    Evacuate air for approximately 10 minutes or more to remove any remaining refrigerant integrated to the compressor oil, etc.

    : GO TO 8.

  8. REPLACE OR REPAIR REFRIGERANT SYSTEM PARTS 
    1. Replace or repair the malfunctioning part.
      CAUTION:
      • Always use a new O-ring for the parts that the cooler system was removed.
      • Apply compressor oil to the O-rings of piping when installing the piping. However, never apply it to the threads.
    2. Adjust the compressor oil amount according to the replaced parts. Refer to "MAINTENANCE OF LUBRICANT QUANTITY ".

      : GO TO 9.

  9. EVACUATE AIR FROM THE REFRIGERANT SYSTEM 

    Evacuate air from the refrigerant system for approximately 25 minutes or more.

    CAUTION: Evacuate air for at least approximately 15 minutes or more if the parts are replaced.

    : GO TO 10.

  10. CHECK AIRTIGHTNESS OF REFRIGERANT SYSTEM 

    Check the airtightness of the refrigerant system for approximately 25 minutes or more.

    CAUTION: Check the airtightness for at least approximately 15 minutes or more if the parts are replaced.

    Does the pressure decrease? 

    YES: GO TO 11.

    NO: GO TO  8.

  11. CHECK REFRIGERANT LEAKAGE 
    1. Connect refrigerant recovery/recycling recharging equipment or manifold gauge set (SST: J-39183).
    2. Charge the refrigerant of approximately 200 g (7.05 oz) to the refrigerant system.
    3. Check for refrigerant leakage. Refer to "INSPECTION ".
      NOTE: When using electrical leak detector (SST: J-41995). Refer to "INSPECTION ".

      Is the inspection result normal? 

      YES: GO TO 12.

      NO: Repair or replace parts according to the inspection results.

  12. CHARGE REFRIGERANT 
    1. Connect recovery/recycling recharging equipment or manifold gauge set (SST: J-39183).
    2. Evacuate air again.
    3. Charge the specified amount of refrigerant to the refrigerant system.

      : GO TO 13.

  13. CHECK REFRIGERANT LEAKAGE 

    Check for refrigerant leakage again. Refer to "INSPECTION ".

    NOTE: When using electrical leak detector (SST: J-41995). Refer to "INSPECTION ".

    Is the inspection result normal? 

    YES: GO TO 14.

    NO: GO TO  6.

  14. CHECK OPERATION 

    Check the A/C system for normal operation. Refer to "INSPECTION ".

    Is the inspection result normal? 

    YES: GO TO 15.

    NO: Repair or replace parts according to the inspection results.

  15. CHECK RECOVERY/RECYCLING RECHARGING EQUIPMENT 
    1. Disconnect recovery/recycling recharging equipment or manifold gauge set (SST: J-39183).
    2. Discharge the refrigerant from the high-pressure hose and low-pressure hose of the recovery/recycling recharging equipment.
    3. Install the service valve caps.

      : INSPECTION END