Setting Of Service Tools And Equipment: Procedure
- CHECK A/C SYSTEM
- Check that A/C system operates normally. Refer to "WITHOUT ACCS: DESCRIPTION & INSPECTION " (Without ACCS) or "WITH ACCS: DESCRIPTION & INSPECTION " (With ACCS).
- Check if there is a large amount of leakage of refrigerant or oil.CAUTION: Never perform the lubricant return operation if a large amount of leakage of lubricant is detected.
Is the inspection result normal?
YES: GO TO 2.
NO: Check for refrigerant leakage. Refer to "INSPECTION ".
- LUBRICANT RETURN OPERATION
- Start the engine and run it as follows.
- Engine speed: Idle - 1, 200 RPM
- A/C switch: ON
- Fan (blower) speed: Maximum speed set
- Set temperature: Full cold
- Intake position: Recirculation (REC)
- Perform lubricant return operation for approximately 10 minutes.
- Stop the engine.
: GO TO 3.
- Start the engine and run it as follows.
- CHECK RECOVERY/RECYCLING RECHARGING EQUIPMENT
- Operate recovery/recycling recharging equipment.CAUTION:
- Follow the instructions of the manufacturer for the handling or maintenance of the equipment.
- Never fill the equipment with undesignated refrigerant.
- Check the gauge pressure of recovery/recycling recharging equipment.
Is there pressure?
YES: GO TO 4.
NO: GO TO 5.
- Operate recovery/recycling recharging equipment.
- DISCHARGE REFRIGERANT INSIDE PIPES
Discharge the refrigerant from the high-pressure hose and low-pressure hose of recovery/recycling recharging equipment.
: GO TO 5.
- CONNECT RECOVERY/RECYCLING RECHARGING EQUIPMENT
- Remove the service valve caps from the vehicle.
- Connect recovery/recycling recharging equipment to the service valves.
: GO TO 6.
- DISCHARGE REFRIGERANT FROM THE VEHICLE
Operate recovery/recycling recharging equipment to discharge the refrigerant from the vehicle.
: GO TO 7.
- REMOVE ANY REMAINING REFRIGERANT
Evacuate air for approximately 10 minutes or more to remove any remaining refrigerant integrated to the compressor oil, etc.
: GO TO 8.
- REPLACE OR REPAIR REFRIGERANT SYSTEM PARTS
- Replace or repair the malfunctioning part.CAUTION:
- Always use a new O-ring for the parts that the cooler system was removed.
- Apply compressor oil to the O-rings of piping when installing the piping. However, never apply it to the threads.
- Adjust the compressor oil amount according to the replaced parts. Refer to
"MAINTENANCE OF LUBRICANT QUANTITY ".
: GO TO 9.
- Replace or repair the malfunctioning part.
- EVACUATE AIR FROM THE REFRIGERANT SYSTEM
Evacuate air from the refrigerant system for approximately 25 minutes or more.
CAUTION: Evacuate air for at least approximately 15 minutes or more if the parts are replaced.: GO TO 10.
- CHECK AIRTIGHTNESS OF REFRIGERANT SYSTEM
Check the airtightness of the refrigerant system for approximately 25 minutes or more.
CAUTION: Check the airtightness for at least approximately 15 minutes or more if the parts are replaced.Does the pressure decrease?
YES: GO TO 11.
NO: GO TO 8.
- CHECK REFRIGERANT LEAKAGE
- Connect refrigerant recovery/recycling recharging equipment or manifold gauge set (SST: J-39183).
- Charge the refrigerant of approximately 200 g (7.05 oz) to the refrigerant system.
- Check for refrigerant leakage. Refer to
"INSPECTION ".NOTE: When using electrical leak detector (SST: J-41995). Refer to "INSPECTION ".
Is the inspection result normal?
YES: GO TO 12.
NO: Repair or replace parts according to the inspection results.
- CHARGE REFRIGERANT
- Connect recovery/recycling recharging equipment or manifold gauge set (SST: J-39183).
- Evacuate air again.
- Charge the specified amount of refrigerant to the refrigerant system.
: GO TO 13.
- CHECK REFRIGERANT LEAKAGE
Check for refrigerant leakage again. Refer to "INSPECTION ".
NOTE: When using electrical leak detector (SST: J-41995). Refer to "INSPECTION ".Is the inspection result normal?
YES: GO TO 14.
NO: GO TO 6.
- CHECK OPERATION
Check the A/C system for normal operation. Refer to "INSPECTION ".
Is the inspection result normal?
YES: GO TO 15.
NO: Repair or replace parts according to the inspection results.
- CHECK RECOVERY/RECYCLING RECHARGING EQUIPMENT
- Disconnect recovery/recycling recharging equipment or manifold gauge set (SST: J-39183).
- Discharge the refrigerant from the high-pressure hose and low-pressure hose of the recovery/recycling recharging equipment.
- Install the service valve caps.
: INSPECTION END