Diagnosis Procedure
- CHECK DTC WITH ICC SENSOR INTEGRATED UNIT
Refer to "DIAGNOSIS DESCRIPTION ".
Are any DTCs detected?
YES: Perform the Diagnosis Procedure corresponding to the detected DTC.
NO: GO TO 2.
- CHECK OVERALL FUNCTION-I
With CONSULT
- Turn ignition switch ON.
- Select "BRAKE SW1" in "DATA MONITOR" mode with CONSULT.
- Check "BRAKE SW1" indication under the following conditions.
Monitor item Condition Indication BRAKE SW1 (ICC brake switch) Brake pedal Slightly depressed OFF Fully released ON
Without CONSULT
- Turn ignition switch ON.
- Check the voltage between ECM harness connector terminals under the following conditions.
ECM Condition Voltage (V) Connector + - Terminal Terminal M160 117 (ICC brake switch signal) 128 Brake pedal Slightly depressed Approx. 0 Fully released Battery voltage Is the inspection result normal?
YES: GO TO 3.
NO: GO TO 4.
- CHECK OVERALL FUNCTION-II
With CONSULT
Select "BRAKE SW2" and check indication under the following conditions.
Monitor item Condition Indication BRAKE SW2 (Stop lamp switch) Brake pedal Slightly depressed ON Fully released OFF Without CONSULT
Check the voltage between ECM harness connector terminals under the following conditions.
ECM Condition Voltage (V) Connector + - Terminal Terminal M160 110 (Stop lamp switch signal) 128 Brake pedal Slightly depressed Battery voltage Fully released Approx. 0 Is the inspection result normal?
YES: GO TO 16.
NO: GO TO 11.
- CHECK ICC BRAKE SWITCH POWER SUPPLY CIRCUIT-I
- Turn ignition switch OFF.
- Disconnect ICC brake switch harness connector.
- Turn ignition switch ON.
- Check the voltage between ICC brake switch harness connector and ground.
ICC brake switch Ground Voltage Connector Terminal E114 1 Ground Battery voltage Is the inspection result normal?
YES: GO TO 8.
NO: GO TO 5.
- CHECK ICC BRAKE SWITCH POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF.
- Disconnect ICC brake hold relay.
- Turn ignition switch ON.
- Check the voltage between ICC brake hold relay harness connector and ground.
ICC brake hold relay Ground Voltage Connector Terminal E91 3 Ground Battery voltage Is the inspection result normal?
YES: GO TO 7.
NO: GO TO 6.
- DETECT MALFUNCTIONING PART
Check the following.
- Fuse block (J/B) connector E103
- 10 A fuse (No. 3)
- Harness for open or short between ICC brake hold relay and fuse
: Repair open circuit or short to ground in harness or connectors.
- CHECK ICC BRAKE SWITCH POWER SUPPLY CIRCUIT-III
- Turn ignition switch OFF.
- Check the continuity between ICC brake switch harness connector and ICC brake hold relay harness connector.
ICC brake switch ICC brake hold relay Continuity Connector Terminal Connector Terminal E114 1 E91 4 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 16.
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK ICC BRAKE SWITCH INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between ICC brake switch harness connector and ECM harness connector.
ICC brake switch ECM Continuity Connector Terminal Connector Terminal E114 2 M160 117 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 10.
NO: GO TO 9.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E106, M6
- Harness for open or short between ICC brake switch and ECM
: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK ICC BRAKE SWITCH
Refer to "COMPONENT INSPECTION (ICC BRAKE SWITCH) ".
Is the inspection result normal?
YES: GO TO 16.
NO: Replace ICC brake switch. Refer to "EXPLODED VIEW ".
- CHECK STOP LAMP SWITCH POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect stop lamp switch harness connector.
- Disconnect ICC brake hold relay.
- Check the voltage between stop lamp switch harness connector and ground.
Stop lamp switch Ground Voltage Connector Terminal E110 3 Ground Battery voltage - Check the voltage between ICC brake hold relay harness connector and ground.
ICC brake hold relay Ground Voltage Connector Terminal E91 7 Ground Battery voltage Is the inspection result normal?
YES: GO TO 13.
NO: GO TO 12.
- DETECT MALFUNCTIONING PART
Check the following.
- Fuse block (J/B) connector E103
- 10 A fuse (No. 7)
- Harness for open or short between battery and stop lamp switch
- Harness for open or short between battery and ICC brake hold relay
: Repair open circuit or short to ground in harness or connectors.
- CHECK STOP LAMP SWITCH INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Disconnect ECM harness connector.
- Check the continuity between stop lamp switch harness connector and ECM harness connector.
Stop lamp switch ECM Continuity Connector Terminal Connector Terminal E110 4 M160 110 Existed - Check the continuity between ICC brake hold relay harness connector and ECM harness connector.
ICC brake hold relay ECM Continuity Connector Terminal Connector Terminal E91 6 M160 110 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 15.
NO: GO TO 14.
- DETECT MALFUNCTIONING PART
Check the following.
- Fuse block (J/B) connector E103, M2
- Harness for open or short between ECM and stop lamp switch
- Harness for open or short between ECM and ICC brake hold relay
: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK STOP LAMP SWITCH
Refer to "COMPONENT INSPECTION (STOP LAMP SWITCH) ".
Is the inspection result normal?
YES: GO TO 16.
NO: Replace stop lamp switch. Refer to "EXPLODED VIEW ".
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
: INSPECTION END