Diagnosis Procedure
- CHECK OIL PRESSURE WARNING LAMP
Perform auto active test. Refer to "DIAGNOSIS DESCRIPTION ".
Does oil pressure warning lamp blink?
YES: GO TO 2.
NO: Replace combination meter.
- CHECK IPDM E/R OUTPUT VOLTAGE
- Disconnect the oil pressure switch connector.
- Turn ignition switch ON.
- Check voltage between the oil pressure switch harness connector and ground.
Terminals Voltage (+) (-) Oil pressure switch Ground Connector Terminal F37 1 Approx. 12 V Is the inspection result normal?
YES: GO TO 3.
NO: GO TO 4.
- CHECK OIL PRESSURE SWITCH UNIT
Perform a unit check for the oil pressure switch. Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION ".
NO: Replace oil pressure switch.
- CHECK OIL PRESSURE SWITCH SIGNAL CIRCUIT
Check the oil pressure switch signal circuit. Refer to "DIAGNOSIS PROCEDURE ".
Is the inspection result normal?
YES: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair harness or connector.