Diagnosis Procedure
- CHECK HARNESS BETWEEN INVERTER UNIT AND AC 120 V OUTLET MAIN SWITCH
- Turn ignition switch OFF.
- Disconnect inverter unit connector and AC 120 V outlet main switch connector.
- Check for continuity between the inverter unit harness connector and AC 120 V outlet main switch harness connector.
Inverter unit AC 120 V outlet main switch Continuity Connector Terminal Connector Terminal M143 6 M144 3 Existed - Check for continuity between inverter unit harness connector and ground.
Inverter unit Ground Continuity Connector Terminal M143 6 Not existed Is the inspection result normal?
YES: GO TO 2.
NO: Repair the harnesses or connectors.
- CHECK AC 120 V OUTLET MAIN SWITCH INPUT SIGNAL
- Connect inverter unit connector and AC 120 V outlet main switch connector.
- Turn ignition switch ON.
- AC 120 V outlet main switch ON.
- Check for voltage between the inverter unit harness connector and ground.
Terminals Condition Voltage (Approx.) (+) (-) Inverter unit Ground AC 120 V outlet main switch Connector Terminal M143 6 OFF 0 V ON 12 V Is the inspection result normal?
YES: INSPECTION END
NO: GO TO 3.
- CHECK AC 120 V OUTLET MAIN SWITCH
- Turn ignition switch OFF.
- Remove AC 120 V outlet main switch.
- Check AC 120 V outlet main switch. Refer to
"COMPONENT INSPECTION ".
Is the inspection result normal?
YES: INSPECTION END
NO: Replace AC 120 V outlet main switch.