Diagnosis Procedure
- CHECK HARNESS BETWEEN INVERTER UNIT AND AC 120 V OUTLET MAIN SWITCH
- Turn ignition switch OFF.
- Disconnect inverter unit connector and AC 120 V outlet main switch connector.
- Check continuity between inverter unit harness connector and AC 120 V main switch harness connector.
Inverter unit AC 120 V outlet main switch Continuity Connector Terminal Connector Terminal M143 7 M144 5 Existed - Check continuity between inverter unit harness connector and ground.
Inverter unit Ground Continuity Connector Terminal M143 7 Not existed Is the inspection result normal?
YES: GO TO 2.
NO: Repair the harnesses or connectors.
- CHECK AC 120 V OUTLET MAIN SWITCH GROUND CIRCUIT
Check continuity between AC 120 V outlet main switch harness connector and ground.
AC 120 V outlet main switch Ground Continuity Connector Terminal M144 6 Existed Is the inspection result normal?
YES: GO TO 3.
NO: Repair the harnesses or connectors.
- CHECK AC 120 V OUTLET MAIN SWITCH INDICATOR OUTPUT SIGNAL
- Connect AC 120 V outlet main switch connector and inverter unit connector.
- Turn ignition switch ON.
- AC 120 V outlet main switch ON. (AC 120 V output is normal)
- Check for voltage between the inverter unit harness connector and ground.
Terminals Condition Voltage (Approx.) (+) (-) Inverter unit Ground AC 120 V outlet main switch Connector Terminal M143 7 OFF 0 V ON 5.2 V Is the inspection result normal?
YES: GO TO 4.
NO: Replace inverter unit.
- CHECK AC 120 V OUTLET MAIN SWITCH INDICATOR
- AC 120 V outlet main switch ON. (AC 120 V output is normal)
- Check that AC 120 V outlet main switch indicator is illuminated.
Is the inspection result normal?
YES: INSPECTION END
NO: Replace AC 120 V outlet main switch.