Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection M95. Refer to Ground Inspection in
"CIRCUIT INSPECTION
".
Is the inspection result normal?
YES: GO TO 2.
NO: Repair or replace ground connection.
- RETIGHTEN AIR FUEL RATIO SENSOR 1
Loosen and retighten the air fuel ratio (A/F) sensor 1. Refer to "DISASSEMBLY AND ASSEMBLY ".
GO TO 3.
- CHECK EXHAUST GAS LEAKAGE
- Start engine and run it at idle.
- Listen for an exhaust gas leakage before three way catalyst (manifold).
Is exhaust gas leakage detected?
YES: Repair or replace malfunctioning part.
NO: GO TO 4.
- CHECK FOR INTAKE AIR LEAKAGE
Listen for an intake air leakage after the mass air flow sensor.
Is intake air leakage detected?
YES: Repair or replace malfunctioning part.
NO: GO TO 5.
- CLEAR THE MIXTURE RATIO SELF-LEARNING VALUE
- Clear the mixture ratio self-learning value. Refer to "MIXTURE RATIO SELF-LEARNING VALUE CLEAR : SPECIAL REPAIR REQUIREMENT ".
- Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0171, P172, P0174 or P0175 detected? Is it difficult to start engine?
YES: Perform trouble diagnosis for DTC P0171, P0174 or P0172, P0175. Refer to "DTC LOGIC " or "DTC LOGIC ".
NO: GO TO 6.
- CHECK A/F SENSOR 1 POWER SUPPLY CIRCUIT
- Disconnect A/F sensor 1 harness connector.
- Turn ignition switch ON.
- Check the voltage between A/F sensor 1 harness connector and ground.VOLTAGE REFERENCE CHART
DTC A/F sensor Ground Voltage Bank Connector Terminal P0133 1 F67 4 Ground Battery voltage P0153 2 F68 4 Is the inspection result normal?
YES: GO TO 8.
NO: GO TO 7.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E10, F10
- IPDM E/R harness connector E7
- 15 A fuse (No. 46)
- Harness for open or short between A/F sensor 1 and fuse
Repair or replace harness or connectors.
- CHECK A/F SENSOR 1 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between A/F sensor 1 harness connector and ECM harness connector.CONTINUITY REFERENCE CHART
DTC A/F sensor 1 ECM Continuity Bank Connector Terminal Connector Terminal P0133 1 F67 1 F111 81 Existed 2 82 P0153 2 F68 1 85 2 86 - Check the continuity between A/F sensor 1 harness connector and ground, or ECM harness connector and ground.CONTINUITY REFERENCE CHART
DTC A/F sensor 1 ECM Ground Continuity Bank Connector Terminal Connector Terminal P0133 1 F67 1 F111 81 Ground Not existed 2 82 P0153 2 F68 1 85 2 86 - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 9.
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK A/F SENSOR 1 HEATER
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 10.
NO: GO TO 13.
- CHECK MASS AIR FLOW SENSOR
Check both mass air flow sensor (bank 1) and mass air flow sensor (bank 2).
Refer to "TYPE A : COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 11.
NO: Replace malfunctioning mass air flow sensor. Refer to "EXPLODED VIEW ".
- CHECK PCV VALVE
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 12.
NO: Repair or replace PCV valve. Refer to "EXPLODED VIEW ".
- CHECK INTERMITTENT INCIDENT
Perform "INTERMITTENT INCIDENT ".
Is the inspection result normal?
YES: GO TO 13.
NO: Repair or replace malfunctioning part.
- REPLACE A/F SENSOR 1
Replace malfunctioning A/F sensor 1. Refer to "EXPLODED VIEW ".
CAUTION:- Discard any A/F sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
- Before installing new A/F sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner [commercial service tool (J-43897-18 or J-43897-12)] and approved anti-seize lubricant (commercial service tool).
INSPECTION END