Component Inspection
- CHECK METER CONTROL SWITCH UNIT
- Turn the ignition switch OFF.
- Disconnect the meter control switch connector.
- Check continuity between the following terminals of the meter control switch:
Combination meter Operation and status Continuity Connector Terminal M54 6 2 Press • (select) switch Existed Other than the above Not existed 7 2 Press □ (enter) switch Existed Other than the above Not existed 3 2 Press Illumination decrease - (illumination control) switch Existed Other than the above Not existed 1 2 Press Illumination decrease + (illumination control) switch Existed Other than the above Not existed Is the inspection result normal?
YES: INSPECTION END
NO: Replace the meter control switch.