Diagnosis Procedure
- CHECK TRIP A/B RESET SWITCH INPUT SIGNAL
- Turn ignition switch ON.
- Measure voltage between the combination meter harness connector terminals.
Combination meter Condition Voltage (Approx.) Connector Terminal (+) (-) M53 38 16 When trip A/B reset switch is pressed 0 V Other than the above 5 V Is the inspection result normal?
YES: INSPECTION END
NO: GO TO 2.
- CHECK TRIP A/B RESET SWITCH SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect the combination meter and meter control switch connectors.
- Check continuity between combination meter harness connector and trip A/B reset switch harness connector.
Combination meter Trip A/B reset switch Continuity Connector Terminal Connector Terminal M53 38 M56 1 Existed 16 2 - Check continuity between combination meter harness connector and ground.
Combination meter Ground Continuity Connector Terminal M53 38 Not existed 16 Is the inspection result normal?
YES: INSPECTION END
NO: Repair harness or connector.