Diagnosis Procedure
- CHECK METER CONTROL SWITCH INPUT SIGNAL
- Turn ignition switch ON.
- Measure voltage between the following terminals of the combination meter:
Combination meter Condition Voltage (Approx.) Connector Terminal (+) (-) M53 36 16 When • (select) switch is pressed 0 V Other than the above 5 V 37 16 When □ (enter) switch is pressed 0 V Other than the above 5 V 39 16 When illumination control - switch is pressed 0 V Other than the above 5 V 40 16 When illumination control - switch is pressed 0 V Other than the above 5 V Is the inspection result normal?
YES: INSPECTION END
NO: GO TO 2.
- CHECK METER CONTROL SWITCH SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect the combination meter and meter control switch connectors.
- Check continuity between combination meter harness connector and meter control switch harness connector.
Combination meter Meter control switch Continuity Connector Terminal Connector Terminal M53 16 M54 2 Existed 36 6 37 7 39 3 40 1 - Check continuity between combination meter harness connector and ground.
Combination meter Ground Continuity Connector Terminal M53 16 Not existed 36 37 39 40 Is the inspection result normal?
YES: INSPECTION END
NO: Repair harness or connector.