Component Inspection
- CHECK METER CONTROL SWITCH UNIT
- Turn ignition switch OFF.
- Disconnect the meter control switch connector.
- Check continuity between the following terminals of the meter control switch:
Combination meter Operation and status Continuity Connector Terminal M54 6 2 Press • (select) switch Existed Other than the above Not existed 7 2 Press □ (enter) switch Existed Other than the above Not existed 3 2 Press illumination control - switch Existed Other than the above Not existed 1 2 Press illumination control + switch Existed Other than the above Not existed Is inspection result normal?
YES: INSPECTION END
NO: Replace meter control switch.