Diagnosis Procedure
- CHECK UNIFIED METER AND A/C AMP. INPUT SIGNAL
- CHECK FUEL LEVEL SENSOR (SUB) CIRCUIT
- Turn ignition switch OFF.
- Disconnect unified meter and A/C amp. connector and fuel level sensor unit (sub) connector.
- Check continuity between unified meter and A/C amp. harness connector and fuel level sensor unit (sub) harness connector.
Unified meter and A/C amp. Fuel level sensor unit (sub) Continuity Connector Terminal Connector terminal M67 42 B21 1 Existed - Check continuity between unified meter and A/C amp. harness connector and ground.
Unified meter and A/C amp. Ground Continuity Connector Terminal M67 42 Not existed Is the inspection result normal?
YES: GO TO 3.
NO: Repair harness or connector.
- CHECK FUEL LEVEL SENSOR (MAIN-SUB) CIRCUIT
- Disconnect fuel level sensor unit and fuel pump (main) connector.
- Check continuity between fuel level sensor unit (sub) harness connector and fuel level sensor unit and fuel pump (main) harness connector.
Fuel level sensor unit (sub) Fuel level sensor unit and fuel pump (main) Continuity Connector Terminal Connector terminal B21 2 B22 2 Existed - Check continuity between fuel level sensor unit (sub) harness connector and ground.
Fuel level sensor unit (sub) Ground Continuity Connector Terminal B21 2 Not existed Is the inspection result normal?
YES: GO TO 4.
NO: Repair harness or connector.
- CHECK FUEL LEVEL SENSOR (MAIN) CIRCUIT
Check continuity between fuel level sensor unit and fuel pump (main) harness connector and unified meter and A/C amp. harness connector.
Fuel level sensor unit and fuel pump (main) Unified meter and A/C amp. Continuity Connector Terminal Connector terminal B22 5 M67 58 Existed Is the inspection result normal?
YES: INSPECTION END
NO: Repair harness or connector.