Diagnosis Procedure
WARNING: This page is about a different variant/trim than selected.
- CHECK TRANSFER ROTARY POSITION SENSOR SIGNAL
- Turn the ignition switch ON.
- Check the voltage between transfer control unit harness connector and ground.VOLTAGE SPECIFICATION
+ - Voltage Transfer control unit Connector Terminal E59 15 Ground Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 2.
- CHECK TRANSFER ROTARY POSITION SENSOR POWER SUPPLY
- Turn the ignition switch OFF.
- Disconnect transfer rotary position sensor harness connector.
- Turn the ignition switch ON.CAUTION: Never start the engine.
- Check the voltage between transfer rotary position sensor harness connector terminals.VOLTAGE SPECIFICATION
+ - Voltage Transfer rotary position sensor Connector Terminal F41 1 2 Approx. 5 V Is the inspection result normal?
YES: GO TO 4.
NO: GO TO 3.
- CHECK TRANSFER ROTARY POSITION SENSOR CIRCUIT
- Turn the ignition switch OFF.
- Disconnect transfer control unit harness connector.
- Check the continuity between transfer control unit harness connector and transfer rotary position sensor harness connector.CONTINUITY SPECIFICATION
Transfer control unit Transfer rotary position sensor Continuity Connector Terminal Connector Terminal E59 18 F41 1 Existed 16 2 - Check the continuity between transfer rotary position sensor harness connector and ground.CONTINUITY SPECIFICATION
Transfer rotary position sensor - Continuity Connector Terminal F41 1 Ground Not existed Is the inspection result normal?
YES: GO TO 5.
NO: Repair or replace error-detected parts.
- CHECK TRANSFER ROTARY POSITION SENSOR SIGNAL CIRCUIT
- Turn the ignition switch OFF.
- Disconnect transfer control unit harness connector.
- Check the continuity between transfer control unit harness connector and transfer rotary position sensor harness connector.CONTINUITY SPECIFICATION
Transfer control unit Transfer rotary position sensor Continuity Connector Terminal Connector Terminal E59 15 F41 3 Existed - Check the continuity between transfer rotary position sensor harness connector and ground.CONTINUITY SPECIFICATION
Transfer rotary position sensor - Continuity Connector Terminal F41 3 Ground Not existed Is the inspection result normal?
YES: GO TO 5.
NO: Repair or replace error-detected parts.
- REPLACE TRANSFER ROTARY POSITION SENSOR
- Replace transfer rotary position sensor. Refer to "REMOVAL AND INSTALLATION ".
- Perform confirmation procedure again. Refer to
"DTC LOGIC ".
Is DTC "P180D" detected?
YES: GO TO 6.
NO: INSPECTION END
- CHECK TERMINALS AND HARNESS CONNECTORS
Check the pin terminals for damage or loose connection with each harness connector.
Is the inspection result normal?
YES: Replace transfer control unit. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace error-detected parts.