Component Inspection
- CHECK TRUNK ROOM LAMP SWITCH
- Turn ignition switch OFF.
- Disconnect trunk lid lock assembly connector.
- Check continuity between trunk lid lock assembly terminals.TERMINALS CONTINUITY REFERENCE CHART
Terminal Condition Continuity Trunk lid lock assembly 1 2 Trunk lid Open Existed Closed Not existed Is the inspection result normal?
YES: INSPECTION END
NO: Replace trunk lid lock assembly. Refer to "TRUNK LID ASSEMBLY : REMOVAL AND INSTALLATION ".