Diagnosis Procedure
- CHECK TRUNK LID OPENER SWITCH INPUT SIGNAL
- Turn ignition switch OFF.
- Disconnect trunk lid opener switch connector.
- Check signal between trunk lid opener switch harness connector and ground using oscilloscope.TRUNK LID OPENER SWITCH INPUT SIGNAL REFERENCE CHART
(+) (-) Signal (Reference value) Trunk lid opener switch Connector Terminal M20 1 Ground Is the inspection result normal?
YES: GO TO 3.
NO: GO TO 2.
- CHECK TRUNK LID OPENER SWITCH CIRCUIT
- Disconnect BCM connector.
- Check continuity between BCM harness connector and trunk lid opener switch harness connector.TERMINALS CONTINUITY REFERENCE CHART
BCM Trunk lid opener switch Continuity Connector Terminal Connector Terminal M121 67 M20 1 Existed - Check continuity between BCM harness connector and ground.TERMINALS CONTINUITY REFERENCE CHART
BCM Ground Continuity Connector Terminal M121 67 Not existed Is the inspection result normal?
YES: Replace BCM. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair harness or connector.
- CHECK TRUNK LID OPENER SWITCH GROUND CIRCUIT
Check continuity between trunk lid opener switch harness connector and ground.
TERMINALS CONTINUITY REFERENCE CHARTTrunk lid opener switch Ground Continuity Connector Terminal M20 2 Existed Is the inspection result normal?
YES: GO TO 4.
NO: Repair or replace harness.
- CHECK TRUNK LID OPENER SWITCH
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 5.
NO: Replace trunk lid opener switch. Refer to "REMOVAL AND INSTALLATION ".
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END