Component Inspection
- CHECK DOOR SWITCH
- Turn ignition switch OFF.
- Disconnect malfunctioning door switch connector.
- Check continuity between door switch terminals.TERMINALS CONTINUITY REFERENCE CHART
Terminal Condition Continuity Door switch 2 Ground part of door switch Door switch Pressed Not existed Released Existed Is the inspection result normal?
YES: INSPECTION END
NO: Replace malfunction door switch. Refer to "REMOVAL AND INSTALLATION ".