Diagnosis Procedure
- CHECK TURN SIGNAL LAMP BULB
Check the applicable lamp bulb.
Is the bulb normal?
YES: GO TO 2.
NO: Replace the bulb.
- CHECK TURN SIGNAL LAMP OUTPUT VOLTAGE
CONSULT-III ACTIVE TEST
- Turn the ignition switch OFF.
- Disconnect the front combination lamp connector or the rear combination lamp connector.
- Turn the ignition switch ON.
- Select "FLASHER" of BCM (FLASHER) active test item.
- With operating the turn signal switch, check the voltage between the BCM harness connector and the ground.
Front
VOLTAGE REFERENCE CHARTTerminals Test item Voltage (Approx.) (+) (-) BCM Ground FLASHER Connector Terminal RH M119 17 RH Off 0 V LH 18 LH Off 0 V Rear
VOLTAGE REFERENCE CHARTTerminals Test item Voltage (Approx.) (+) (-) BCM Ground FLASHER Connector Terminal RH M120 20 RH Off 0 V LH 25 LH Off 0 V Is the measurement value normal?
YES: GO TO 3.
NO: Replace BCM.
- CHECK TURN SIGNAL LAMP OPEN CIRCUIT
- Turn the ignition switch OFF.
- Disconnect BCM connector.
- Check the continuity between the BCM harness connector and the front combination lamp or the rear combination lamp harness connector.
Front combination lamp
CONTINUITY REFERENCE CHARTBCM Front combination lamp Continuity Connector Terminal Connector Terminal RH M119 17 E28 6 Existed LH 18 E58 6 Rear combination lamp
CONTINUITY REFERENCE CHARTBCM Rear combination lamp Continuity Connector Terminal Connector Terminal RH M120 20 B67 4 Existed LH 25 B60 4 Does continuity exist?
YES: GO TO 4.
NO: Repair the harnesses or connectors.
- CHECK TURN SIGNAL LAMP SHORT CIRCUIT
Check continuity between the BCM harness connector and the ground.
Front
CONTINUITY REFERENCE CHARTBCM Ground Continuity Connector Terminal RH M119 17 Not existed LH 18 Rear
CONTINUITY REFERENCE CHARTBCM Ground Continuity Connector Terminal RH M120 20 Not existed LH 25 Does continuity exist?
YES: Repair the harnesses or connectors.
NO: GO TO 5.
- CHECK TURN SIGNAL LAMP GROUND OPEN CIRCUIT
Check the voltage between the BCM harness connector and the front combination lamp or the rear combination lamp and the ground.
Front combination lamp
CONTINUITY REFERENCE CHARTFront combination lamp Ground Continuity Connector Terminal RH E28 4 Existed LH E58 4 Rear combination lamp
CONTINUITY REFERENCE CHARTRear combination lamp Ground Continuity Connector Terminal RH B67 3 Existed LH B60 3 Does continuity exist?
YES: Replace the front combination lamp or the rear combination lamp.
NO: Repair the harnesses or connectors.