Diagnosis Procedure
- CHECK BCM INPUT SIGNAL
- Connect the CONSULT-III.
- Check the BCM input signals. Refer to
"COMPONENT FUNCTION CHECK
".
Is the inspection result normal?
YES: Go to 2.
NO: Go to 3.
- CHECK UNIFIED METER AND A/C AMP. INPUT SIGNAL
Select the "Data Monitor" for the "METER/M&A" and check the "TRUNK/GLAS-H" monitor value.
"TRUNK/GLAS-H"
Trunk lid open : On
Trunk lid closed : Off
Is the inspection result normal?
YES: Replace combination meter.
NO: Replace BCM.
- CHECK TRUNK ROOM LAMP SWITCH SIGNAL CIRCUIT
Check the trunk room lamp switch signal circuit. Refer to "DIAGNOSIS PROCEDURE ".
Is the inspection result normal?
YES: Go to 4.
NO: Repair harness or connector.
- CHECK TRUNK ROOM LAMP SWITCH
Check the trunk room lamp switch. Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: Replace combination meter.
NO: Replace trunk lid lock assembly. Refer to "TRUNK LID LOCK : REMOVAL AND INSTALLATION ".