Diagnosis Procedure

  1. CHECK UNIFIED METER AND A/C AMP. INPUT SIGNAL
    1. Turn ignition switch ON.
    2. Check voltage between unified meter and A/C amp. harness connector terminal and ground.
      VOLTAGE REFERENCE CHART

      Terminal Voltage (Approx.)
      (+) (-)
      Unified meter and A/C amp.
      Connector Terminal
      M67 42 Ground
      G07159210Courtesy of NISSAN MOTOR CO., U.S.A.

      Does it match fuel gauge reading? 

      YES: Go to 2.

      NO: Replace the unified meter and A/C amp.

  2. CHECK FUEL LEVEL SENSOR (SUB) CIRCUIT
    1. Turn ignition switch OFF.
    2. Disconnect unified meter and A/C amp. connector and fuel level sensor unit (sub) connector.
    3. Check continuity between unified meter and A/C amp. harness connector terminal and fuel level sensor unit (sub) harness connector terminal.
      CONTINUITY REFERENCE CHART

      Unified meter and A/C amp. Fuel level sensor unit (sub) Continuity
      Connector Terminal Connector Terminal
      M67 42 B21 1 Existed
    4. Check continuity between unified meter and A/C amp. harness connector terminal and ground.
      CONTINUITY REFERENCE CHART

      Unified meter and A/C amp. Ground Continuity
      Connector Terminal
      M67 42 Not existed

      Is the inspection result normal? 

      OK: Go to 3.

      NG: Repair harness or connector.

  3. CHECK FUEL LEVEL SENSOR (MAIN-SUB) CIRCUIT
    1. Disconnect fuel level sensor unit and fuel pump (main) connector.
    2. Check continuity between fuel level sensor unit (sub) harness connector terminal and fuel level sensor unit and fuel pump (main) harness connector terminal.
      CONTINUITY REFERENCE CHART

      Fuel level sensor unit (sub) Fuel level sensor unit (main) Continuity
      Connector Terminal Connector Terminal
      B21 2 B22 2 Existed
    3. Check continuity between fuel level sensor unit (sub) harness connector terminal and ground.
      CONTINUITY REFERENCE CHART

      Fuel level sensor unit (sub) Ground Continuity
      Connector Terminal
      B21 2 Not existed

      Is the inspection result normal? 

      OK: Go to 4.

      NG: Repair harness or connector.

  4. CHECK FUEL LEVEL SENSOR (MAIN) CIRCUIT

    Check continuity between fuel level sensor unit and fuel pump (main) harness connector terminal and unified meter and A/C amp. harness connector terminal.

    CONTINUITY REFERENCE CHART

    Fuel level sensor unit (main) Unified meter and A/C amp. Continuity
    Connector Terminal Connector Terminal
    B22 5 M67 58 Existed

    Is the inspection result normal? 

    OK: INSPECTION END

    NG: Repair harness or connector.