Diagnosis Procedure
- CHECK REMOTE KEYLESS ENTRY RECEIVER OUTPUT SIGNAL
- Turn ignition switch OFF.
- Check signal between remote keyless entry receiver harness connector and ground using oscilloscope.SIGNAL REFERENCE CHART
(+) (-) Condition Signal (Reference value) Remote keyless entry receiver Connector Terminal M104 2 Ground Waiting (All door closed) When signal is received (All door closed) Is the inspection result normal?
YES: GO TO 3.
NO: GO TO 2.
- CHECK REMOTE KEYLESS ENTRY RECEIVER CIRCUIT 1
- Disconnect BCM connector and remote keyless entry receiver connector
- Check continuity between BCM harness connector and remote keyless entry receiver harness connector.CONTINUITY REFERENCE CHART
BCM Remote keyless entry receiver Continuity Connector Terminal Connector Terminal M122 83 M104 2 Existed - Check continuity between BCM harness connector and ground.CONTINUITY REFERENCE CHART
BCM Ground Continuity Connector Terminal M122 83 Not existed Is the inspection result normal?
YES: Replace BCM. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.
- CHECK REMOTE KEYLESS ENTRY RECEIVER POWER SUPPLY
- Disconnect remote keyless entry receiver.
- Check voltage between remote keyless entry receiver harness connector and ground.VOLTAGE REFERENCE CHART
(+) (-) Voltage (V) (Approx.) Remote keyless entry receiver Connector Terminal M104 4 Ground Battery voltage Is the inspection result normal?
YES: GO TO 5.
NO: GO TO 4.
- CHECK REMOTE KEYLESS ENTRY RECEIVER CIRCUIT 2
- Disconnect BCM connector.
- Check continuity between BCM harness connector and remote keyless entry receiver harness connector.CONTINUITY REFERENCE CHART
BCM Remote keyless entry receiver Continuity Connector Terminal Connector Terminal M122 103 M104 4 Existed - Check continuity between BCM harness connector and ground.CONTINUITY REFERENCE CHART
BCM Ground Continuity Connector Terminal M122 103 Not existed Is the inspection result normal?
YES: Replace BCM. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.
- CHECK REMOTE KEYLESS ENTRY RECEIVER GROUND CIRCUIT
Check continuity between remote keyless entry receiver harness connector and ground.
CONTINUITY REFERENCE CHARTRemote keyless entry receiver Ground Continuity Connector Terminal M104 1 Existed Is the inspection result normal?
YES: Replace remote keyless entry receiver. Refer to "REMOVAL AND INSTALLATION ".
NO: GO TO 6.
- CHECK REMOTE KEYLESS ENTRY RECEIVER CIRCUIT 3
- Disconnect BCM connector.
- Check continuity between BCM harness connector and remote keyless entry receiver harness connector.CONTINUITY REFERENCE CHART
BCM Remote keyless entry receiver Continuity Connector Terminal Connector Terminal M123 137 M104 1 Existed Is the inspection result normal?
YES: Replace BCM. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.