Diagnosis Procedure
- CHECK INSTALLATION OF TOUCH SENSOR RH
Check that touch sensor RH is installed normally.
Refer to "TOUCH SENSOR : REMOVAL AND INSTALLATION ".
Is the inspection result normal?
YES: GO TO 2.
NO: Refer to "TOUCH SENSOR : REMOVAL AND INSTALLATION ".
- CHECK TOUCH SENSOR MONITOR ITEM
- Select "AUTOMATIC BACK DOOR CONTROL UNIT" using CONSULT-III.
- Select "TOUCH SEN RH" in "DATA MONITOR" mode.
- Check that the function operates normally according to the following conditions.MONITOR ITEMS CONDITION CHART
Monitor item Condition Status TOUCH SEN RH Touch sensor RH Other than below OFF Detect obstruction ON Is the inspection result normal?
YES: GO TO 8.
NO: GO TO 3.
- CHECK TOUCH SENSOR INPUT SIGNAL
- Turn ignition switch OFF.
- Check voltage between touch sensor RH harness connector and automatic back door control unit harness connector.VOLTAGE REFERENCE CHART
(+) (-) Condition Voltage (Approx.) Touch sensor RH Automatic back door control unit Connector Terminal Connector Terminal D126 1 B207 13 Touch sensor RH Detect obstruction 1.8 - 5 V Other than above 2.72 - 7.27 V Is the inspection result normal?
YES: GO TO 5.
NO: GO TO 4.
- CHECK TOUCH SENSOR RH CIRCUIT
- Disconnect automatic back door control unit and touch sensor RH connector.
- Check continuity between automatic back door control unit harness connector and touch sensor RH harness connector.CONTINUITY REFERENCE CHART
Automatic back door control unit Touch sensor RH Continuity Connector Terminal Connector Terminal B207 1 D126 1 Existed - Check continuity between automatic back door control unit harness connector and ground.CONTINUITY REFERENCE CHART
Automatic back door control unit Ground Continuity Connector Terminal B207 1 Not existed Is the inspection result normal?
YES: Replace automatic back door control unit. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.
- CHECK TOUCH SENSOR RH GROUND CIRCUIT
- Disconnect automatic back door control unit and touch sensor RH connector.
- Check continuity between automatic back door control unit harness connector and touch sensor RH harness connector.CONTINUITY REFERENCE CHART
Automatic back door control unit Touch sensor RH Continuity Connector Terminal Connector Terminal B207 13 D126 2 Existed - Check continuity between automatic back door control unit harness connector and ground.CONTINUITY REFERENCE CHART
Automatic back door control unit Ground Continuity Connector Terminal B207 13 Not existed Is the inspection result normal?
YES: GO TO 6.
NO: Repair or replace harness.
- CHECK TOUCH SENSOR RH GROUND CIRCUIT 2
- Connect automatic back door control unit and touch sensor RH connector.
- Check voltage between automatic back door control unit harness connector and ground.VOLTAGE REFERENCE CHART
(+) (-) Voltage (Approx.) Automatic back door control unit Connector Terminal B207 13 Ground 0.01 - 0 V Is the inspection result normal?
YES: GO TO 7.
NO: Replace automatic back door control unit. Refer to "REMOVAL AND INSTALLATION ".
- CHECK TOUCH SENSOR RH
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 8.
NO: Replace touch sensor RH.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".