Diagnosis Procedure
- CHECK AUTOMATIC BACK DOOR CLOSE SWITCH INPUT SIGNAL
- Turn ignition switch OFF.
- Disconnect automatic back door close switch connector.
- Check voltage between automatic back door close switch harness connector and ground.VOLTAGE REFERENCE CHART
(+) (-) Voltage (Approx.) Automatic back door close switch Connector Terminal D113 1 Ground 16 V Is the inspection result normal?
YES: GO TO 3.
NO: GO TO 2.
- CHECK AUTOMATIC BACK DOOR CLOSE SWITCH CIRCUIT
- Disconnect automatic back door control unit connector.
- Check continuity between automatic back door control unit harness connector and automatic back door close switch harness connector.CONTINUITY REFERENCE CHART
Automatic back door control unit Automatic back door close switch Continuity Connector Terminal Connector Terminal B207 23 D113 1 Existed - Check continuity between automatic back door control unit harness connector and ground.CONTINUITY REFERENCE CHART
Automatic back door control unit Ground Continuity Connector Terminal B207 23 Not existed Is the inspection result normal?
YES: Replace automatic back door control unit. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.
- CHECK AUTOMATIC BACK DOOR CLOSE SWITCH GROUND CIRCUIT
Check continuity between automatic back door close switch harness connector and ground.
CONTINUITY REFERENCE CHARTAutomatic back door close switch Ground Continuity Connector Terminal D113 2 Existed Is the inspection result normal?
YES: GO TO 4.
NO: Repair or replace harness.
- CHECK AUTOMATIC BACK DOOR CLOSE SWITCH
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 5.
NO: Replace automatic back door close switch.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END