Diagnosis Procedure
- CHECK AUTOMATIC BACK DOOR SWITCH INPUT SIGNAL
- Turn ignition switch OFF.
- Disconnect automatic back door switch connector.
- Check voltage between automatic back door switch harness connector and ground.VOLTAGE REFERENCE CHART
(+) (-) Voltage (Approx.) Automatic back door switch Connector Terminal M34 1 Ground 16 V Is the inspection result normal?
YES: GO TO 3.
NO: GO TO 2.
- CHECK AUTOMATIC BACK DOOR SWITCH CIRCUIT
- Disconnect automatic back door control unit connector.
- Check continuity between automatic back door control unit harness connector and automatic back door switch harness connector.CONTINUITY REFERENCE CHART
Automatic back door control unit Automatic back door switch Continuity Connector Terminal Connector Terminal B207 22 M34 1 Existed - Check continuity between automatic back door control unit harness connector and ground.CONTINUITY REFERENCE CHART
Automatic back door control unit Ground Continuity Connector Terminal B207 22 Not existed Is the inspection result normal?
YES: Replace automatic back door control unit. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.
- CHECK AUTOMATIC BACK DOOR SWITCH GROUND CIRCUIT
Check continuity between automatic back door switch harness connector and ground.
CONTINUITY REFERENCE CHARTAutomatic back door switch Ground Continuity Connector Terminal M34 2 Existed Is the inspection result normal?
YES: GO TO 4.
NO: Repair or replace harness.
- CHECK AUTOMATIC BACK DOOR SWITCH
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 5.
NO: Replace automatic back door switch.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END