Diagnosis Procedure
- CHECK FUSE
- Turn ignition switch OFF.
- Check 10 A fuse, [No. 9, located in fuse block (J/B)].
Is fuse fusing?
YES: Replace the blown fuse after repairing the affected circuit if a fuse is blown.
NO: GO TO 2.
- CHECK KEY SLOT ILLUMINATION OUTPUT SIGNAL
Check voltage between key slot harness connector and ground.
VOLTAGE REFERENCE CHART(+) (-) Condition Key slot illumination Voltage (V) (Approx.) Key slot Connector Terminal M22 6 Ground Intelligent Key inserted OFF Battery voltage Intelligent Key removed ON 0 Is the inspection result normal?
YES: GO TO 3.
NO: GO TO 4.
- CHECK KEY SLOT CIRCUIT
- Disconnect BCM and key slot connector.
- Check continuity between BCM harness connector and key slot harness connector.CONTINUITY REFERENCE CHART
BCM Key slot Continuity Connector Terminal Connector Terminal M122 92 M22 6 Existed - Check continuity between BCM harness connector and ground.CONTINUITY REFERENCE CHART
BCM Ground Continuity Connector Terminal M122 92 Not existed Is the inspection result normal?
YES: Replace BCM. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.
- CHECK KEY SLOT POWER SUPPLY CIRCUIT
- CHECK KEY SLOT GROUND CIRCUIT
Check continuity between key slot harness connector and ground.
CONTINUITY REFERENCE CHARTKey slot Ground Continuity Connector Terminal M22 7 Existed Is the inspection result normal?
YES: GO TO 6.
NO: Repair or replace harness.
- CHECK KEY SLOT
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 7.
NO: Replace key slot. Refer to "REMOVAL AND INSTALLATION ".
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END