Diagnosis Procedure
- CHECK BACK DOOR CONTROL UNIT OUTPUT
- Turn ignition switch OFF.
- Disconnect back door lock assembly connector.
- Check voltage between back door lock assembly harness connector and ground.VOLTAGE REFERENCE CHART
(-) (-) Voltage (V) (Approx.) Half latch switch Connector Terminal D122 6 Ground Battery voltage Is the inspection result normal?
YES: GO TO 3.
NO: GO TO 2.
- CHECK HALF LATCH SWITCH CIRCUIT
- Disconnect back door control unit connector.
- Check continuity between back door control unit harness connector.CONTINUITY REFERENCE CHART
Back door control unit Back door lock assembly Continuity Connector Terminal Connector Terminal D123 2 D122 6 Existed - Check continuity between back door control unit harness connector and ground.CONTINUITY REFERENCE CHART
Back door control unit Ground Continuity Connector Terminal D123 2 Not existed Is the inspection result normal?
YES: Replace back door control unit. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.
- CHECK HALF LATCH SWITCH GROUND CIRCUIT
Check continuity between back door lock assembly harness connector and ground.
CONTINUITY REFERENCE CHARTBack door lock assembly Ground Continuity Connector Terminal D122 8 Existed Is the inspection result normal?
YES: GO TO 4.
NO: Repair or replace harness.
- CHECK HALF LATCH SWITCH
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 5.
NO: Replace back door lock assembly. Refer to "REMOVAL AND INSTALLATION ".
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END