Diagnosis Procedure
- CHECK FUEL LID LOCK ACTUATOR INPUT SIGNAL
- Turn ignition switch OFF.
- Disconnect fuel lid lock actuator connector.
- Check voltage between fuel lid lock actuator harness connector and ground.VOLTAGE REFERENCE CHART
(+) (-) Condition of door lock and unlock switch Voltage (V) (Approx.) Fuel lid lock actuator Connector Terminal B242 1 Ground Unlock 0 → Battery voltage → 0 2 Lock 0 → Battery voltage → 0 Is the inspection result normal?
YES: Replace fuel lid lock actuator. Refer to "REMOVAL AND INSTALLATION ".
NO: GO TO 2.
- CHECK FUEL LID LOCK ACTUATOR CIRCUIT
- Disconnect BCM connector.
- Check continuity between BCM harness connector and fuel lid lock actuator harness connector.CONTINUITY REFERENCE CHART
BCM Fuel lid lock actuator Continuity Connector Terminal Connector Terminal M119 8 B242 2 Existed 9 1 - Check continuity between BCM harness connector and ground.CONTINUITY REFERENCE CHART
BCM Ground Continuity Connector Terminal M119 8 Not existed 9 Is the inspection result normal?
YES: Replace BCM. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.