Diagnosis Procedure
- CHECK BACK DOOR CONTROL UNIT INPUT SIGNAL
- Turn ignition switch OFF.
- Disconnect back door control unit.
- Check voltage between back door control unit harness connector and ground.VOLTAGE REFERENCE CHART
(+) (-) Condition Voltage (V) (Approx.) Back door control unit Connector Terminal D123 6 Ground Back door opener switch Not pressed Battery voltage Pressed 0 Is the inspection result normal?
YES: GO TO 4.
NO: GO TO 2.
- CHECK BACK DOOR CONTROL UNIT CIRCUIT
- Disconnect BCM connector.
- Check continuity between back door control unit harness connector and BCM harness connector.CONTINUITY REFERENCE CHART
Back door control unit BCM Continuity Connector Terminal Connector Terminal D123 6 M121 48 Existed - Check continuity between BCM harness connector and ground.CONTINUITY REFERENCE CHART
BCM Ground Continuity Connector Terminal M121 48 Not existed Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace harness.
- CHECK BCM OUTPUT SIGNAL
- Connect BCM connector.
- Check voltage between BCM harness connector and ground.VOLTAGE REFERENCE CHART
(+) (-) Condition Voltage (V) (Approx.) BCM Connector Terminal M121 48 Ground Back door opener switch Not pressed Battery voltage Pressed 0 Is the inspection result normal?
YES: GO TO 4.
NO: Replace BCM. Refer to "REMOVAL AND INSTALLATION ".
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END