Diagnosis Procedure
- INSPECTION START
Confirm the detected malfunction (A or B). Refer to DTC LOGIC .
Which malfunction is detected?
A: GO TO 2
B: GO TO 9.
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection M95. Refer to Ground Inspection in
CIRCUIT INSPECTION
.
Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace ground connection.
- CHECK HEATED OXYGEN SENSOR 2 CONNECTOR
- Disconnect heated oxygen sensor 2 (HO2S2) harness connector.
- Check that water is not inside connectors.
Is the inspection result normal?
YES: GO TO 4.
NO: Repair or replace harness or connectors.
- CHECK HO2S2 GROUND CIRCUIT FOR OPEN AND SHORT
- Disconnect ECM harness connector.
- Check the continuity between HO2S2 harness connector and ECM harness connector.CONTINUITY REFERENCE TABLE
DTC HO2S2 ECM Continuity Bank Connector Terminal Connector Terminal P0138 1 F87 1 F110 31 Existed P0158 2 F88 1 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 5.
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between HO2S2 harness connector and ECM harness connector.CONTINUITY REFERENCE TABLE
DTC HO2S2 ECM Continuity Bank Connector Terminal Connector Terminal P0138 1 F87 4 F110 32 Existed P0158 2 F88 4 36 - Check the continuity between HO2S2 harness connector and ground, or ECM harness connector and ground.CONTINUITY REFERENCE TABLE
DTC HO2S2 ECM Ground Continuity Bank Connector Terminal Connector Terminal P0138 1 F87 4 F110 32 Ground Not existed P0158 2 F88 4 36 - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 6.
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- Check the continuity between HO2S2 harness connector and ECM harness connector.
- CHECK HEATED OXYGEN SENSOR 2
Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES: GO TO 8.
NO: GO TO 7.
- REPLACE HEATED OXYGEN SENSOR 2
Replace malfunctioning heated oxygen sensor 2.
CAUTION:- Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
- Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner [commercial service tool (J-43897-18 or J-43897-12)] and approved anti-seize lubricant (commercial service tool).
INSPECTION END
- CHECK INTERMITTENT INCIDENT
Refer to INTERMITTENT INCIDENT .
INSPECTION END
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection M95. Refer to Ground Inspection in
CIRCUIT INSPECTION
.
Is the inspection result normal?
YES: GO TO 10.
NO: Repair or replace ground connection.
- CLEAR THE MIXTURE RATIO SELF-LEARNING VALUE
- Clear the mixture ratio self-learning value. Refer to MIXTURE RATIO SELF-LEARNING VALUE CLEAR: SPECIAL REPAIR REQUIREMENT .
- Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0172 or P0175 detected? Is it difficult to start engine?
YES: Perform trouble diagnosis for DTC P0172, P0175. Refer to DTC LOGIC .
NO: GO TO 11.
- CHECK HEATED OXYGEN SENSOR 2 GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect heated oxygen sensor 2 (HO2S2) harness connector.
- Disconnect ECM harness connector.
- Check the continuity between HO2S2 harness connector and ECM harness connector.CONTINUITY REFERENCE TABLE
DTC HO2S2 ECM Continuity Bank Connector Terminal Connector Terminal P0138 1 F87 1 F110 31 Existed P0158 2 F88 1 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 12.
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between HO2S2 harness connector and ECM harness connector.CONTINUITY REFERENCE TABLE
DTC HO2S2 ECM Continuity Bank Connector Terminal Connector Terminal P0138 1 F87 4 F110 32 Existed P0158 2 F88 4 36 - Check the continuity between HO2S2 harness connector and ground, or ECM harness connector and ground.CONTINUITY REFERENCE TABLE
DTC HO2S2 ECM Ground Continuity Bank Connector Terminal Connector Terminal P0138 1 F87 4 F110 32 Ground Not existed P0158 2 F88 4 36 - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 13.
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- Check the continuity between HO2S2 harness connector and ECM harness connector.
- CHECK HEATED OXYGEN SENSOR 2
Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES: GO TO 15.
NO: GO TO 14.
- REPLACE HEATED OXYGEN SENSOR 2
Replace malfunctioning heated oxygen sensor 2.
CAUTION:- Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
- Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner [commercial service tool (J-43897-18 or J-43897-12)] and approved anti-seize lubricant (commercial service tool).
INSPECTION END
- CHECK INTERMITTENT INCIDENT
Refer to INTERMITTENT INCIDENT .
INSPECTION END