Diagnosis Procedure
- CHECK TRIP A/B RESET SWITCH SIGNAL CIRCUIT
Check the trip A/B reset switch signal circuit. Refer to "DIAGNOSIS PROCEDURE ".
Is the inspection result normal?
YES: GO TO 2.
NO: Repair harness or connector.
- CHECK TRIP A/B RESET SWITCH UNIT
Perform a unit check for the trip A/B reset switch. Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: Replace combination meter.
NG: Replace trip A/B reset switch.