Physical Values
UNIFIED METER AND A/C AMP CONNECTOR TERMINALS REFERENCE CHART
| Terminal No. (Wire color) | Description | Condition | Value (Approx.) | |||
|---|---|---|---|---|---|---|
| + | - | Signal name | Input/Output | |||
| 5 (L) | Ground | Manual mode shift up signal | Input | Ignition switch ON | Selector lever UP operation | 0 V |
| Other than the above | 12 V | |||||
| 7 (GR) | Ground | Communication signal (AMP. → METER) | Output | Ignition switch ON | - | |
| 8 (L) | Ground | Vehicle speed signal (2-pulse) | Output | Ignition switch ON | Speedometer operated [When vehicle speed is approx. 40 km/h (25 MPH)] |
NOTE:
The maximum voltage varies depending on the specification (destination unit).
|
| 9 (SB) | Ground | Seat belt buckle switch signal (driver side) | Input | Ignition switch ON | When seat belt is fastened | 12 V |
| When seat belt is not fastened | 0 V | |||||
| 10 (W) | Ground | Manual mode signal | Input | Ignition switch ON | Selector lever DS position | 0 V |
| Other than the above | 12 V | |||||
| 11 (G) | Ground | Not manual mode signal | Input | Ignition switch ON | Selector lever DS position | 12 V |
| Other than the above | 0 V | |||||
| 14 (BR) | Ground | Communication signa.l(LCD → AMP. | Input | Ignition switch ON | - | |
| 25 (V) | Ground | Manual mode shift down signal | Input | Ignition switch ON | Selector lever down operation | 0 V |
| Other than the above | 12 V | |||||
| 27 (LG) | Ground | Communication signal. METER → AMP. | Input | Ignition switch ON | - | |
| 28 (R) | Ground | Vehicle speed signal (8-pulse) | Output | Ignition switch ON | Speedometer operated [When vehicle speed is approx. 40 km/h (25 MPH)] |
NOTE:
The maximum voltage varies depending on the specification (destination unit).
|
| 30 (V) | Ground | Parking brake switch signal | Input | Ignition switch ON | Parking brake is applied | 0 V |
| Parking brake is released | ||||||
| 34 (Y) | Ground | Communication signal (AMP. → LCD) | Output | Ignition switch ON | - | |
| 41 (V) | Ground | ACC power supply | Input | Ignition switch ACC | - | Battery voltage |
| 42 (Y) | Ground | Fuel level sensor signal | Input | Ignition switch ON | - | |
| 45 (P) | Ground | Ambient sensor signal | Input | - | - | |
| 53 (G) | Ground | Ignition signal | Input | Ignition switch ON | - | Battery voltage |
| 54 (Y) | Ground | Battery power supply | Input | Ignition switch OFF | - | Battery voltage |
| 55 (B) | Ground | Ground | - | Ignition switch ON | - | 0 V |
| 56 (L) | Ground | CAN-H | - | - | - | - |
| 57 (W) | Ground | Brake fluid level switch signal | Input | Ignition switch ON | Brake fluid level is normal. | 5 V |
| The brake fluid level is lower than the low level | 0 V | |||||
| 58 (BR) | Ground | Fuel level sensor signal ground | - | Ignition switch ON | - | 0 V |
| 61 (BR) | Ground | Ambient sensor signal ground | - | Ignition switch ON | - | 0 V |
| 71 (B) | Ground | Ground | - | Ignition switch ON | - | 0 V |
| 72 (P) | Ground | CAN-L | - | - | - | - |