Diagnosis Procedure
- CHECK UNIFIED METER AND A/C AMP. INPUT SIGNAL
- Turn ignition switch ON.
- Check voltage between unified meter and A/C amp. harness connector and ground.VOLTAGE REFERENCE CHART
Terminals Voltage (Approx.) (+) (-) Unified meter and A/C amp. Ground Connector Terminal M67 42 Does it match fuel gauge reading?
YES: GO TO 2.
NO: Replace unified meter and A/C amp.
- CHECK FUEL LEVEL SENSOR (SUB) CIRCUIT
- Turn ignition switch OFF.
- Disconnect unified meter and A/C amp. connector and fuel level sensor unit (sub) connector.
- Check continuity between unified meter and A/C amp. harness connector and fuel level sensor unit (sub) harness connector.CONTINUITY REFERENCE CHART
Unified meter and A/C amp. Fuel level sensor unit (sub) Continuity Connector Terminal Connector terminal M67 42 B21 1 Existed - Check continuity between unified meter and A/C amp. harness connector and ground.CONTINUITY REFERENCE CHART
Unified meter and A/C amp. Ground Continuity Connector Terminal M67 42 Not existed Is the inspection result normal?
YES: GO TO 3.
NO: Repair harness or connector.
- CHECK FUEL LEVEL SENSOR (MAIN-SUB) CIRCUIT
- Disconnect fuel level sensor unit and fuel pump (main) connector.
- Check continuity between fuel level sensor unit (sub) harness connector and fuel level sensor unit and fuel pump (main) harness connector.CONTINUITY REFERENCE CHART
Fuel level sensor unit (sub) Fuel level sensor unit and fuel pump (main) Continuity Connector Terminal Connector terminal B21 2 B22 2 Existed - Check continuity between fuel level sensor unit (sub) harness connector and ground.CONTINUITY REFERENCE CHART
Fuel level sensor unit (sub) Ground Continuity Connector Terminal B21 2 Not existed Is the inspection result normal?
YES: GO TO 4.
NO: Repair harness or connector.
- CHECK FUEL LEVEL SENSOR (MAIN) CIRCUIT
Check continuity between fuel level sensor unit and fuel pump (main) harness connector and unified meter and A/C amp. harness connector.
CONTINUITY REFERENCE CHARTFuel level sensor unit and fuel pump (main) Unified meter and A/C amp. Continuity Connector Terminal Connector terminal B22 5 M67 58 Existed Is the inspection result normal?
YES: INSPECTION END
NO: Repair harness or connector.