Diagnosis Procedure
- CHECK TRUNK LID OPEN INPUT SIGNAL
- Remove Intelligent Key from key slot.
- Turn ON trunk lid opener cancel switch.
- Check voltage between BCM harness connector and ground.TERMINALS VOLTAGE REFERENCE
Terminals Condition of trunk lid opener switch Voltage (V) (Approx.) (+) (-) BCM connector Terminal M121 67 Ground ON (press and hold) 0 OFF (release)
Is the inspection result normal?
YES: GO TO 5.
NO: GO TO 2.
- CHECK TRUNK LID OPENER SWITCH CIRCUIT
- Disconnect BCM connector and trunk lid opener switch connector.
- Check continuity between BCM harness connector and trunk lid opener switch harness connector.TERMINALS CONTINUITY REFERENCE
BCM connector Terminal Trunk lid opener switch connector Terminal Continuity M121 67 M20 1 Existed - Check continuity between BCM harness connector and ground.TERMINALS CONTINUITY REFERENCE
BCM connector Terminal Ground Continuity M121 67 Not existed
Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace harness or connector.
- CHECK TRUNK LID OPENER SWITCH GROUND CIRCUIT
Check continuity between trunk lid opener switch harness connector and ground.
TERMINALS CONTINUITY REFERENCETrunk lid opener switch connector Terminal Ground Continuity M20 2 Existed Is the inspection result normal?
YES: GO TO 4.
NO: Repair or replace harness.
- CHECK TRUNK LID OPENER SWITCH
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 5.
NO: Replace trunk lid opener switch. Refer to "REMOVAL AND INSTALLATION ".
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END