Diagnosis Procedure
- CHECK UNIFIED METER AND A/C AMP. INPUT SIGNAL
- Turn ignition switch ON.
- Check voltage between unified meter and A/C amp. harness connector terminal and ground.
TERMINAL VOLTAGE CHARTTerminal Voltage (Approx.) (+) (-) Unified meter and A/C amp. Connector Terminal M67 42 Ground Does it match fuel gauge reading?
YES: GO TO 2.
NO: Replace the unified meter and A/C amp.
- CHECK FUEL LEVEL SENSOR (SUB) CIRCUIT
- Turn ignition switch OFF.
- Disconnect unified meter and A/C amp. connector and fuel level sensor unit (sub) connector.
- Check continuity between unified meter and A/C amp. harness connector terminal and fuel level sensor unit (sub) harness connector terminal.CONNECTOR TERMINAL CONTINUITY CHART
Unified meter and A/C amp. Fuel level sensor unit (sub) Continuity Connector Terminal Connector Terminal M67 42 B21 1 Existed - Check continuity between unified meter and A/C amp. harness connector terminal and ground.CONNECTOR TERMINAL CONTINUITY CHART
Unified meter and A/C amp. Ground Continuity Connector Terminal M67 42 Not existed Is the inspection result normal?
OK: GO TO 3.
NG: Repair harness or connector.
- CHECK FUEL LEVEL SENSOR (MAIN-SUB) CIRCUIT
- Disconnect fuel level sensor unit and fuel pump (main) connector.
- Check continuity between fuel level sensor unit (sub) harness connector terminal and fuel level sensor unit and fuel pump (main) harness connector terminal.CONNECTOR TERMINAL CONTINUITY CHART
Fuel level sensor unit (sub) Fuel level sensor unit (main) Continuity Connector Terminal Connector Terminal B21 2 B22 2 Existed - Check continuity between fuel level sensor unit (sub) harness connector terminal and ground.
CONNECTOR TERMINAL CONTINUITY CHARTFuel level sensor unit (sub) Ground Continuity Connector Terminal B21 2 Not existed Is the inspection result normal?
OK: GO TO 4.
NG: Repair harness or connector.
- CHECK FUEL LEVEL SENSOR (MAIN) CIRCUIT
Check continuity between fuel level sensor unit and fuel pump (main) harness connector terminal and unified meter and A/C amp. harness connector terminal.
CONNECTOR TERMINAL CONTINUITY CHARTFuel level sensor unit (main) Unified meter and A/C amp. Continuity Connector Terminal Connector Terminal B22 5 M67 58 Existed Is the inspection result normal?
OK: GO TO 5.
NG: Repair harness or connector.
- CHECK INSTALLATION CONDITION
Check fuel level sensor unit installation, and check whether the float arm interferes or binds with any of the internal components in the fuel tank.
Is the inspection result normal?
YES: INSPECTION END
NO: Install the fuel level sensor unit properly.