Component Inspection
- CHECK METER CONTROL SWITCH UNIT
- Turn the ignition switch OFF.
- Disconnect the meter control switch connector.
- Check continuity of the meter control switch.CONTINUITY REFERENCE
Connector Terminal No. Operation and status Continuity M54 2 7 Press ◦ switch Yes Other than the above No 1 7 Press □ switch Yes Other than the above No 5 7 Press the trip A/B reset switch. Yes Other than the above No 10 7 Press - switch Yes Other than the above No 9 7 Press + switch Yes Other than the above No
Is inspection result OK?
YES: INSPECTION END
NO: Replace the meter control switch.