Component Inspection
- CHECK METER CONTROL SWITCH UNIT
- Turn the ignition switch OFF.
- Disconnect the meter control switch connector.
- Check continuity between the following terminals of the meter control switch.TERMINALS CONTINUITY TABLE
Combination meter Operation and status Continuity Connector Terminal M54 6 2 Press • (select) switch Existed Other than the above Not existed 7 2 Press enter switch Existed Other than the above Not existed 3 2 Press - illumination control switch Existed Other than the above Not existed 1 2 Press + illumination control switch Existed Other than the above Not existed
Is inspection result normal?
YES: INSPECTION END
NO: Replace the meter control switch.