Component Inspection

  1. CHECK METER CONTROL SWITCH UNIT 
    1. Turn the ignition switch OFF.
    2. Disconnect the meter control switch connector.
    3. Check continuity between the following terminals of the meter control switch.
      TERMINALS CONTINUITY TABLE

      Combination meter Operation and status Continuity
      Connector Terminal
      M54 6 2 Press • (select) switch Existed
      Other than the above Not existed
      7 2 Press enter switch Existed
      Other than the above Not existed
      3 2 Press - illumination control switch Existed
      Other than the above Not existed
      1 2 Press + illumination control switch Existed
      Other than the above Not existed

    Is inspection result normal? 

    YES: INSPECTION END