Diagnosis Procedure
- CHECK UNIFIED METER AND A/C AMP. INPUT SIGNAL
- Turn ignition switch ON.
- Check voltage between unified meter and A/C amp. harness connector M66 terminal 9 and ground.
9 - Ground
When driver seat belt is fastened : Approx. 12 V
When driver seat belt is unfastened : Approx. 0 V
Is the inspection result normal?
YES: Replace unified meter and A/C amp.
NO: GO TO 2.
- CHECK SEAT BELT BUCKLE SWITCH CIRCUIT
- Turn ignition switch OFF.
- Disconnect unified meter and A/C amp. connector and seat belt buckle switch (driver side) connector.
- Check continuity between unified meter and A/C amp. harness connector M66 terminal 9 and seat belt buckle switch (driver side) harness connector B13 terminal 1.
9 - 1 : Continuity should exist.
- Check harness continuity between unified meter and A/C amp. harness connector M66 terminal 9 and ground.
9 - Ground : Continuity should not exist.
Is the inspection result normal?
YES: GO TO 3.
NO: Repair harness or connector.
- CHECK SEAT BELT BUCKLE SWITCH GROUND CIRCUIT
Check harness continuity between seat belt buckle switch (driver side) harness connector B13 terminal 2 and ground.
2 - Ground : Continuity should exist.
Is the inspection result normal?
YES: INSPECTION END
NO: Repair harness or connector.