Check BCM Power Supply and Ground Circuit
- CHECK FUSE
- Check 15A fuse [No. 1, located in fuse block (J/B)]
- Check 15A fuse [No. 22, located in fuse block (J/B)]
- Check 50A fusible link (letter M, located in the fuse and fusible link box).NOTE: Refer to "COMPONENT PARTS AND HARNESS CONNECTOR LOCATION ".
OK or NG
OK : GO TO 2.
NG : If fuse is blown out, be sure to eliminate cause of malfunction before installing new fuse. Refer to "POWER SUPPLY ROUTING CIRCUIT ".
- CHECK POWER SUPPLY CIRCUIT
Check voltage between BCM connector and ground.
TERMINALS VOLTAGE CHARTConnector Terminal (Wire color) Condition of ignition switch Voltage [V] (Approx.) (+) (-) M3 38 (W/L) Ground ON Battery voltage M4 42 (L/R) OFF 55 (G) OK or NG
OK : GO TO 3.
NG : Check BCM power supply circuit for open or short.
- CHECK GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM connector.
- Check continuity between BCM connector M4 terminal 49, 52 and ground.
49 (B) - Ground : Continuity should exist.
52 (B) - Ground : Continuity should exist.
OK or NG
OK : Power supply and ground circuit are OK.
NG : Check BCM ground circuit for open or short.