Front Wiper Does Not Operate
- During IPDM E/R fail-safe control, front wipers may not operate. Refer to "CAN COMMUNICATION LINE CONTROL " in "PG IPDM E/R" to make sure that it is not in fail-safe status.
- ACTIVE TEST
With CONSULT-II
- Select "IPDM E/R" by CONSULT-II, and select "ACTIVE TEST" on "SELECT DIAG MODE" screen.
- Select "FRONT WIPER" on "SELECT TEST ITEM" screen.
- Touch "LO" or "HI" screen.
Without CONSULT-II
Start up auto active test. Refer to "AUTO ACTIVE TEST ".
Does front wiper operate normally?
YES : GO TO 5.
NO : GO TO 2.
- CHECK FRONT WIPER CIRCUIT
- Turn ignition switch OFF.
- Disconnect IPDM E/R connector and front wiper motor connector.
- Check continuity between IPDM E/R harness connector and front wiper motor harness connector terminal.IPDM E/R FRONT WIPER MOTOR CONTINUITY REFERENCE
IPDM E/R Front wiper motor Continuity Connector Terminal Connector Terminal E7 21 E57 1 Yes 31 4 - Check continuity between IPDM E/R harness connector terminal and Ground.IPDM E/R CONNECTOR TERMINAL CONTINUITY REFERENCE
IPDM E/R connector Terminal Ground Continuity E7 21 No 31 OK or NG
OK : GO TO 3.
NG : Repair harness or connector.
- CHECK GROUND CIRCUIT
Check continuity between front wiper motor harness connector E57 terminal 2 and ground.
2 - Ground : Continuity should exist.
OK or NG
OK : GO TO 4.
NG : Repair harness or connector.
- CHECK IPDM E/R
With CONSULT-II
- Connect IPDM E/R connector and front wiper motor connector.
- Select "IPDM E/R" by CONSULT-II, and select "ACTIVE TEST" on "SELECT DIAG MODE" screen.
- Select "FRONT WIPER" on "SELECT TEST ITEM" screen.
- Touch "LO" or "HI" screen.
- Check voltage between IPDM E/R harness connector and ground while front wiper (HI, LO) is operating.
Courtesy of NISSAN MOTOR CO., U.S.A.
IPDM E/R CONNECTOR TERMINAL VOLTAGE REFERENCE(+) (-) Condition Voltage IPDM E/R connector Terminal E7 21 Ground Stopped Approx. 0 V LO operation Battery voltage 31 Stopped Approx. 0 V HI operation Battery voltage
Without CONSULT-II
- Connect IPDM E/R connector and front wiper motor connector.
- Start up auto active test. Refer to "AUTO ACTIVE TEST ".
- Check voltage between IPDM E/R harness connector and ground while front wiper (HI, LO) is operating.IPDM E/R CONNECTOR TERMINAL VOLTAGE REFERENCE
(+) (-) Condition Voltage IPDM E/R connector Terminal E7 21 Ground Stopped Approx. 0 V LO operation Battery voltage 31 Stopped Approx. 0 V HI operation Battery voltage
OK or NG
OK : Replace front wiper motor.
NG : Replace IPDM E/R.
- CHECK CIRCUIT BETWEEN COMBINATION SWITCH AND BCM
With CONSULT-II
- Select "BCM" on CONSULT-II, and select "WIPER" on "SELECT TEST ITEM" screen.
- Select "DATA MONITOR" on "SELECT DIAG MODE" screen. Make sure that "FR WIPER INT""FR WIPER LOW", and "FR WIPER HI" turn ON-OFF according to wiper switch operation.
Without CONSULT-II
Refer to "COMBINATION SWITCH INSPECTION ".
OK or NG
OK : GO TO 6.
NG : Check combination switch (wiper switch). Refer to "COMBINATION SWITCH INSPECTION ".
- CHECK CIRCUIT BETWEEN IPDM E/R AND BCM
Select "BCM" on CONSULT-II, and perform self-diagnosis for "BCM".
Displayed self-diagnosis results
NO DTC : Replace BCM. Refer to "REMOVAL AND INSTALLATION OF BCM ".
CAN COMM CIRCUIT : Check CAN communication line of BCM. Refer to "CAN COMMUNICATION INSPECTION USING CONSULT-II (SELF-DIAGNOSIS) ".