All Signals, Main Signals, Selection From Menu
CONSULT-II SCREEN DISPLAY REFERENCE
| Item name | CONSULT-II screen display | Display or unit | Monitor item selection | Description | ||
|---|---|---|---|---|---|---|
| ALL SIGNALS | MAIN SIGNALS | SELECTION FROM MENU | ||||
| FR wiper request | FR WIP REQ | STOP/LOW/HI | x | x | x | Signal status input from BCM |
| Wiper auto stop | WIP AUTO STOP | ACT P/STOP P | x | x | x | Output status of IPDM E/R |
| Wiper protection | WIP PROT | OFF/BLOCK | x | x | x | Control status of IPDM E/R |
NOTE:
Perform monitoring of IPDM E/R data with ignition switch ON. When ignition switch is at ACC, the display may not be correct.