DTC C1120-C1127, C1164-C1167
INSPECTION PROCEDURE
- CHECK SELF-DIAGNOSTIC RESULTS
Check the self-diagnostic results.
SELF-DIAGNOSTIC RESULTS CHARTSelf-diagnostic results FR LH IN ABS SOL FR LH OUT ABS SOL RR RH IN ABS SOL RR RH OUT ABS SOL FR RH IN ABS SOL FR RH OUT ABS SOL RR LH IN ABS SOL RR LH OUT ABS SOL CV 1 CV 2 SV 1 SV 2 Is the above displayed in the self-diagnosis display items?
YES : GO TO 2.
NO : INSPECTION END
- CHECK CONNECTOR
- Disconnect ABS actuator and electric unit (control unit) connector check terminals for deformation, disconnection, looseness, and so on. If any malfunction is found, repair or replace terminal.
- Securely reconnect connector and perform self-diagnosis.
OK or NG
OK : Connector terminal contact is loose, damaged, open or shorted.
NG : GO TO 3.
- CHECK SOLENOID POWER AND GROUND CIRCUIT
- Turn ignition switch OFF and disconnect ABS actuator and electric unit (control unit) connector E56.
- Check voltage between ABS actuator and electric unit (control unit) harness connector and ground.ABS ACTUATOR AND ELECTRIC UNIT VOLTAGE CHART
ABS actuator and electric unit (control unit) Ground Voltage 32 - Battery voltage (Approx. 12 V) - Check continuity between ABS actuator and electric unit (control unit) harness connector and ground.ABS ACTUATOR AND ELECTRIC UNIT CONTINUITY CHART
ABS actuator and electric unit (control unit) Ground Continuity 16, 47 - Yes
OK or NG
OK : Perform self-diagnosis again. If the same results appear, replace ABS actuator and electric unit (control unit). Refer to "ACTUATOR AND ELECTRIC UNIT (ASSEMBLY) ".
NG : Repair or replace harness or connectors.