Terminals and Reference Values for BCM
TERMINALS AND REFERENCE VALUES CHART
| Terminal No. | Wire color | Signal name | Measuring condition | Reference value | ||
|---|---|---|---|---|---|---|
| Ignition switch | Operation or condition | |||||
| 2 | R | Combination switch input 5 | ON | Lighting, turn, wiper switch (Wiper intermittent dial position 4) |
OFF | Approx. 0 V |
| Turn signal switch to right |
Approx. 1.0 V |
|||||
| 3 | P/L | Combination switch input 4 | ON | Lighting, turn, wiper switch (Wiper intermittent dial position 4) | OFF | Approx. 0 V |
| Turn signal switch to left |
Approx. 1.0 V |
|||||
| 11 | LG | Ignition switch (ACC) | ACC | - | Battery voltage | |
| 29 | G/Y | Hazard switch signal | OFF | Hazard switch | ON | Approx. 0 V |
| OFF | Battery voltage | |||||
| 36 | L/W | Combination switch output 1 | ON | Lighting, turn, wiper switch (Wiper intermittent dial position 4) |
OFF |
Approx. 7.2 V |
Any of the conditions below
|
Approx. 1.2 V |
|||||
| 38 | W/L | Ignition switch (ON) | ON | - | Battery voltage | |
| 39 | L | CAN - H | - | - | - | |
| 40 | P | CAN - L | - | - | - | |
| 42 | L/R | Battery power supply | OFF | - | Battery voltage | |
| 45 | G/W | Flasher output (left) | ON | Combination switch | Turn left ON | |
| 46 | BR/W | Flasher output (right) | ON | Combination switch | Turn right ON | |
| 49 | B | Ground | ON | - | Approx. 0 V | |
| 52 | B | Ground | ON | - | Approx. 0 V | |
| 55 | G | Battery power supply | OFF | - | Battery voltage | |