Out Line
Power is supplied at all times
- through 10A fuse (No. 71, located in IPDM E/R)
- to tail lamp relay, located in IPDM E/R and
- to CPU located in IPDM E/R,
- through 15A fuse (No. 78, located in IPDM E/R)
- to CPU located in IPDM E/R.
Power is also supplied at all times
- through 50A fusible link (letter M, located in fuse, fusible link and relay box)
- to BCM terminal 55,
- through 15A fuse [No. 22, located in fuse block (J/B)]
- to BCM terminal 42,
- through 10A fuse [No. 20, located in fuse block (J/B)]
- to rear combination lamp control unit terminal 1,
- through 10A fuse [No. 19, located in fuse block (J/B)]
- to combination meter terminal 8 and
- to unified meter and A/C amp. terminal 21.
With ignition switch in ON or START position, power is supplied
- through ignition relay, located in IPDM E/R, from battery direct,
- through 15A fuse [No. 1, located in fuse block (J/B)]
- to BCM terminal 38,
- through 10A fuse [No. 12, located in fuse block (J/B)]
- to combination meter terminal 7 and
- to unified meter and A/C amp. terminal 22.
With ignition switch in ACC or ON position, power is supplied
- through 10A fuse [No. 6, located in fuse block (J/B)]
- to BCM terminal 11.
Ground is supplied
- to BCM terminals 49 and 52
- through grounds M35, M45 and M85,
- to IPDM E/R terminals 38 and 60
- through grounds E21, E50 and E51,
- to rear combination lamp control unit terminal 7
- through grounds E21, E50 and E51,
- to combination meter terminals 5, 6 and 15
- through grounds M35, M45 and M85,
- to unified meter and A/C amp. terminals 29 and 30
- through grounds M35, M45 and M85.