All Interior Room Lamps Do Not Operate
- CHECK POWER SUPPLY CIRCUIT
- All interior room lamps switch are OFF.
- Turn ignition switch ON.
- Check voltage between BCM harness connector M4 terminal 41 and ground.
41 - Ground : Battery voltage.
OK or NG
OK : Repair harness or connector. In a case of making a short circuit, be sure to disconnect cable from the negative terminal repairing harness, and then reconnect.
NG : Replace BCM. Refer to "REMOVAL AND INSTALLATION OF BCM ".