Hazard Warning Lamp Does Not Operate But Turn Signal Lamp Operate
- CHECK BULB
Make sure bulb standard of each turn signal lamp is correct.
OK or NG
- OK: GO TO 2.
- NG: Replace bulb.
- CHECK HAZARD SWITCH INPUT SIGNAL
With CONSULT-II
Select "BCM" on CONSULT-II. With "FLASHER" data monitor, make sure "HAZARD SW" turns ON-OFF linked with operation of hazard switch.
When hazard switch is ON: HAZARD SW ON position
Without CONSULT-II
Check voltage between BCM harness connector M1 terminal 29 (G/R) and ground.
Courtesy of NISSAN MOTOR CO., U.S.A.
Courtesy of NISSAN MOTOR CO., U.S.A.
OK or NG
- OK: Replace BCM. Refer to "REMOVAL AND INSTALLATION OF BCM ".
- NG: GO TO 3.
- CHECK HAZARD SWITCH CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM connector and hazard switch connector.
- Check continuity BCM harness connector M1 terminal 29 (G/R) and hazard switch harness connector M282 terminal 2 (G/R).
29 (G/R) - 2 (G/R): Continuity should exist.
OK or NG
- OK: GO TO 4.
- NG: Repair harness or connector.
- CHECK GROUND
Check continuity hazard switch harness connector M282 terminal 1 (B) and ground.
1 (B) - Ground: Continuity should exist.
OK or NG
- OK: GO TO 5.
- NG: Repair harness or connector.
- CHECK HAZARD SWITCH
- Disconnect hazard switch connector.
- Check continuity hazard switch.
OK or NG
- OK: Replace BCM if turn signal lamps does not work after setting the connector again. Refer to "REMOVAL AND INSTALLATION OF BCM ".
- NG: Replace hazard switch.