CONSULT-II Inspection Procedure
CAUTION:
If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carry out CAN communication.
- Turn ignition switch OFF.
- Insert IVIS (NATS) program card into CONSULT-II.
Program card: NATS (AEN01C-1)
- Connect CONSULT-II and CONSULT-II CONVERTER to data link connector.
- Turn ignition switch ON.
- Touch "START (NISSAN BASED VHCL)".
- Touch "OTHER"
- Select "NATS V.5.0".
If "NATS V5.0" is not indicated, go to CONSULT-II DATA LINK CONNECTOR (DLC) CIRCUIT .
- Perform each diagnostic test mode according to each service procedure.